STOMACH |
1 Departments of Gastroenterology and Hepatology, Academic Medical Centre, Amsterdam, the Netherlands
2 Department of Nuclear Medicine, Academic Medical Centre, Amsterdam, the Netherlands
Correspondence to:
Correspondence to:
Dr G E Boeckxstaens
Department of Gastroenterology and Hepatology, Academic Medical Centre, Room C2-211, Meibergdreef 9, 1105 AZ Amsterdam, the Netherlands; g.e.boeckxstaens{at}amc.uva.nl
Background: Recently, single photon emission computed tomography (SPECT) scanning was described as a non-invasive technique to assess fundic accommodation. However, in contrast with the barostat, no intragastric distending force is applied during SPECT scanning. We hypothesised that in the absence of a barostat balloon, SPECT scanning largely detects the volume effect of the ingested meal and is a rather insensitive tool to detect fundic relaxation.
Methods: After an overnight fast, healthy volunteers underwent a barostat study and SPECT scanning on two separate days to assess: (1) meal induced fundic accommodation (Nutridrink, 200 ml, 300 kcal); and (2) gastric relaxation to 1 mg intravenous glucagon.
Results: Fasting fundic volumes (145 (8) v 280 (32) ml; p=0.001) and average postprandial volume (329 (10) v 571 (53) ml; p=0.001) were significantly lower measured with SPECT compared with the barostat study. Meal induced fundic relaxation (183 (10) v 289 (46) ml; p=0.050) and the postprandial/fasting volume ratio (2.32 (0.10) v 2.27 (0.29); p=0.892) did not differ significantly between SPECT scanning and the barostat. However, no correlation could be determined between accommodation volumes measured by both techniques. In contrast with meal induced relaxation, the glucagon induced increase in fundic volume (19 (5) v 406 (56) ml; p=0.007) and post/pre glucagon ratio (1.16 (0.03) v 3.02 (0.54); p=0.046) were significantly lower when measured by SPECT scanning compared with the barostat.
Conclusion: SPECT scanning detects changes in postprandial volume but is less suitable than the gastric barostat in detecting changes in gastric tone. Our study therefore questions its role as a tool to detect impaired accommodation and warrants further validation of this technique.
Keywords: Barostat; dyspepsia; gastric accommodation; single photon emission computed tomography
Abbreviations: SPECT, single photon emission computed tomography; MDP, minimal distending pressure; VAS, visual analogue scale; FD, functional dyspepsia
This article has been cited by other articles:
![]() |
O. Goetze, A. Steingoetter, D. Menne, I. R. van der Voort, M. A. Kwiatek, P. Boesiger, D. Weishaupt, M. Thumshirn, M. Fried, and W. Schwizer The effect of macronutrients on gastric volume responses and gastric emptying in humans: a magnetic resonance imaging study Am J Physiol Gastrointest Liver Physiol, January 1, 2007; 292(1): G11 - G17. [Abstract] [Full Text] [PDF] |
||||
![]() |
I. M. de Zwart, J. J. L. Haans, P. Verbeek, P. H. C. Eilers, A. de Roos, and A. A. M. Masclee Gastric accommodation and motility are influenced by the barostat device: assessment with magnetic resonance imaging Am J Physiol Gastrointest Liver Physiol, January 1, 2007; 292(1): G208 - G214. [Abstract] [Full Text] [PDF] |
||||
![]() |
M W Mundt and M Samsom Fundal dysaccommodation in functional dyspepsia: head-to-head comparison between the barostat and three-dimensional ultrasonographic technique Gut, December 1, 2006; 55(12): 1725 - 1730. [Abstract] [Full Text] [PDF] |
||||
![]() |
S Kindt and J Tack Impaired gastric accommodation and its role in dyspepsia Gut, December 1, 2006; 55(12): 1685 - 1691. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. D. Burton, H. J. Kim, M. Camilleri, D. A. Stephens, B. P. Mullan, M. K. O'Connor, and N. J. Talley Relationship of gastric emptying and volume changes after a solid meal in humans Am J Physiol Gastrointest Liver Physiol, August 1, 2005; 289(2): G261 - G266. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. J. Bennink, B. D. van den Elzen, S. D. Kuiken, and G. E. Boeckxstaens Noninvasive Measurement of Gastric Accommodation by Means of Pertechnetate SPECT: Limiting Radiation Dose Without Losing Image Quality J. Nucl. Med., January 1, 2004; 45(1): 147 - 152. [Abstract] [Full Text] [PDF] |
||||