Gut

HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
[Advanced]

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this link to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Add article to my folders
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fireman, Z
Right arrow Articles by Scapa, E
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fireman, Z
Right arrow Articles by Scapa, E
Gut 2003;52:390-392
© 2003 by BMJ Publishing Group & British Society of Gastroenterology


INFLAMMATORY BOWEL DISEASE IMAGING

Diagnosing small bowel Crohn’s disease with wireless capsule endoscopy

Z Fireman1, E Mahajna1, E Broide2, M Shapiro2, L Fich1, A Sternberg1, Y Kopelman1, E Scapa2

1 Department of Gastroenterology, Hillel-Yaffe Medical Center, Hadera, Israel
2 Department of Gastroenterology, Asaf-Harofe Medical Center, Zrifin, Israel

Correspondence to:
Correspondence to:
Dr Z Fireman, Gastroenterology Department, Hillel Yaffe Medical Center, PO Box 169, Hadera 38100, Israel;
fireman{at}hillel-yaffe.health.gov.il


ABSTRACT
Background: The small bowel is the most commonly affected site of Crohn’s disease (CD) although it may involve any part of the gastrointestinal tract. The current methodologies for examining the small bowel are x ray and endoscopy.

Aims: To evaluate, for the first time, the effectiveness of wireless capsule endoscopy in patients with suspected CD of the small bowel undetected by conventional modalities, and to determine the diagnostic yield of the M2A Given Capsule.

Patients: Seventeen patients (eight males, mean age 40 (15) years) with suspected CD fulfilled study entry criteria: nine had iron deficiency anaemia (mean haemoglobin 10.5 (SD 1.8) g%), eight had abdominal pain, seven had diarrhoea, and three had weight loss. Small bowel x ray and upper and lower gastrointestinal endoscopic findings were normal. Mean duration of symptoms before diagnosis was 6.3 (SD 2.2) years.

Methods: Each subject swallowed an M2A Given Capsule containing a miniature video camera, batteries, a transmitter, and an antenna. Recording time was approximately eight hours. The capsule was excreted naturally in the patient’s bowel movement, and the data it contained were retrieved and interpreted the next day.

Results: Of the 17 study participants, 12 (70.6%, six males, mean age 34.5 (12) years) were diagnosed as having CD of the small bowel according to the findings of the M2A Given Capsule.

Conclusions: Wireless capsule endoscopy diagnosed CD of the small bowel (diagnostic yield of 71%). It was demonstrated as being an effective modality for diagnosing patients with suspected CD undetected by conventional diagnostic methodologies.


Abbreviations: CD, Crohn’s disease; CT, computerised tomography; ESR, erythrocyte sedimentation rate; OGD, oesophagogastroduodenoscopy




This article has been cited by other articles:


Home page
Rheumatology (Oxford)Home page
S. S. Hamdulay, K. Cheent, C. Ghosh, J. Stocks, S. Ghosh, and D. O. Haskard
Wireless capsule endoscopy in the investigation of intestinal Behcet's syndrome
Rheumatology, August 1, 2008; 47(8): 1231 - 1234.
[Abstract] [Full Text] [PDF]


Home page
GutHome page
R Sidhu, D S Sanders, A J Morris, and M E McAlindon
Guidelines on small bowel enteroscopy and capsule endoscopy in adults
Gut, January 1, 2008; 57(1): 125 - 136.
[Full Text] [PDF]


Home page
RadiologyHome page
D. D. T. Maglinte, K. Sandrasegaran, J. C. Lappas, and M. Chiorean
CT Enteroclysis
Radiology, December 1, 2007; 245(3): 661 - 671.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. D. T. Maglinte, K. Sandrasegaran, M. Chiorean, J. Dewitt, L. McHenry, and J. C. Lappas
Radiologic Investigations Complement and Add Diagnostic Information to Capsule Endoscopy of Small-Bowel Diseases
Am. J. Roentgenol., August 1, 2007; 189(2): 306 - 312.
[Abstract] [Full Text] [PDF]


Home page
GutHome page
A Bourreille, M Jarry, P N D'Halluin, E Ben-Soussan, V Maunoury, P Bulois, S Sacher-Huvelin, K Vahedy, E Lerebours, D Heresbach, et al.
Wireless capsule endoscopy versus ileocolonoscopy for the diagnosis of postoperative recurrence of Crohn's disease: a prospective study
Gut, July 1, 2006; 55(7): 978 - 983.
[Abstract] [Full Text] [PDF]


Home page
GutHome page
X C Cao, B M Wang, and Z C Han
Wireless capsule endoscopic finding in Cronkhite-Canada syndrome.
Gut, June 1, 2006; 55(6): 899 - 900.
[Full Text] [PDF]


Home page
BMJHome page
R. Sidhu, D. S Sanders, and M. E McAlindon
Gastrointestinal capsule endoscopy: from tertiary centres to primary care.
BMJ, March 4, 2006; 332(7540): 528 - 531.
[Full Text] [PDF]


Home page
GutHome page
E F Stange, S P L Travis, S Vermeire, C Beglinger, L Kupcinkas, K Geboes, A Barakauskiene, V Villanacci, A Von Herbay, B F Warren, et al.
European evidence based consensus on the diagnosis and management of Crohn's disease: definitions and diagnosis
Gut, March 1, 2006; 55(suppl_1): i1 - i15.
[Full Text] [PDF]


Home page
RadiologyHome page
A. K. Hara, J. A. Leighton, R. I. Heigh, V. K. Sharma, A. C. Silva, G. De Petris, J. G. Hentz, and D. E. Fleischer
Crohn Disease of the Small Bowel: Preliminary Comparison among CT Enterography, Capsule Endoscopy, Small-Bowel Follow-through, and Ileoscopy
Radiology, January 1, 2006; 238(1): 128 - 134.
[Abstract] [Full Text] [PDF]


Home page
GutHome page
J G Albert, F Martiny, A Krummenerl, K Stock, J Lesske, C M Gobel, E Lotterer, H H Nietsch, C Behrmann, and W E Fleig
Diagnosis of small bowel Crohn's disease: a prospective comparison of capsule endoscopy with magnetic resonance imaging and fluoroscopic enteroclysis
Gut, December 1, 2005; 54(12): 1721 - 1727.
[Abstract] [Full Text] [PDF]


Home page
SURG INNOVHome page
B. R. Davis, H. Harris, and G. C. Vitale
The Evolution of Endoscopy: Wireless Capsule Cameras for the Diagnosis of Occult Gastrointestinal Bleeding and Inflammatory Bowel Disease
Surgical Innovation, June 1, 2005; 12(2): 129 - 133.
[Abstract] [PDF]


Home page
QJMHome page
D.R. Gaya, T.D.B. Lyon, A. Duncan, J.B. Neilly, S. Han, J. Howell, C. Liddell, A.J. Stanley, A.J. Morris, and J.F. Mackenzie
Faecal calprotectin in the assessment of Crohn's disease activity
QJM, June 1, 2005; 98(6): 435 - 441.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
A. K. Hara, J. A. Leighton, V. K. Sharma, R. I. Heigh, and D. E. Fleischer
Imaging of Small Bowel Disease: Comparison of Capsule Endoscopy, Standard Endoscopy, Barium Examination, and CT
RadioGraphics, May 1, 2005; 25(3): 697 - 711.
[Abstract] [Full Text] [PDF]


Home page
GutHome page
P Swain
Wireless capsule endoscopy and Crohn's disease
Gut, March 1, 2005; 54(3): 323 - 326.
[Full Text] [PDF]


Home page
GutHome page
W A Voderholzer, J Beinhoelzl, P Rogalla, S Murrer, G Schachschal, H Lochs, and M-A Ortner
Small bowel involvement in Crohn's disease: a prospective comparison of wireless capsule endoscopy and computed tomography enteroclysis
Gut, March 1, 2005; 54(3): 369 - 373.
[Abstract] [Full Text] [PDF]


Home page
GutHome page
P Swain and A Fritscher-Ravens
Role of video endoscopy in managing small bowel disease
Gut, December 1, 2004; 53(12): 1866 - 1875.
[Full Text] [PDF]


Home page
Jpn J Clin OncolHome page
M. Hashizume and K. Tsugawa
Robotic Surgery and Cancer: the Present State, Problems and Future Vision
Jpn. J. Clin. Oncol., May 1, 2004; 34(5): 227 - 237.
[Abstract] [Full Text] [PDF]


Home page
GutHome page
K Schulmann, S Hollerbach, W Schmiegel, Z Fireman, and Y Kopelman
Diagnosing small bowel Crohn's disease with wireless capsule endoscopy * Authors' reply
Gut, October 1, 2003; 52(10): 1531 - 1532.
[Full Text] [PDF]


Home page
JWatch GastroenterologyHome page
Capsule Endoscopy for Diagnosing Crohn's Disease
Journal Watch Gastroenterology, April 29, 2003; 2003(429): 6 - 6.
[Full Text]

eLetters:

Read all eLetters

Yield of capsule endocopy in Crohn's disease may depend on the quality of prior ileo-colonoscopy
Karsten Schulmann, et al.
Gut Online, 11 Mar 2003 [Full text]
Diagnosing small bowel Crohn's disease with wireless capsule eneteroscopy
Zvi Fireman, et al.
Gut Online, 31 Mar 2003 [Full text]



HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
Terms and conditions relating to subscriptions purchased online  ¦  Website terms and conditions  ¦  Privacy policy
Copyright © 2003 BMJ Publishing Group Ltd & British Society of Gastroenterology