Microprocessor controlled movement of solid colonic content using sequential neural electrical stimulation
  1. M A Amaris1,
  2. P Z Rashev2,
  3. M P Mintchev3,
  4. K L Bowes1
  1. 1Department of Surgery, University of Alberta, Edmonton, Alberta, Canada
  2. 2Department of Electrical and Computer Engineering, University of Calgary, Calgary, Alberta, Canada
  3. 3Department of Surgery, University of Alberta, Edmonton, Alberta, Canada and Department of Electrical and Computer Engineering, University of Calgary, Calgary, Alberta, Canada
  1. Correspondence to:
    Professor M P Mintchev, Department of Electrical and Computer Engineering, University of Calgary, 2500 University Drive NW, Calgary, Alberta, Canada T2N 1N4;
    mintchev{at}enel.ucalgary.ca

Abstract

Background and aims: Invoked peristaltic contractions and movement of solid content have not been attempted in normal canine colon. The purpose of this study was to determine if movement of solid content through the colon could be produced by microprocessor controlled sequential stimulation.

Methods: The study was performed on six anaesthetised dogs. At laparotomy, a 15 cm segment of descending colon was selected, the proximal end closed with a purse string suture, and the distal end opened into a collecting container. Four sets of subserosal stimulating electrodes were implanted at 3 cm intervals. The segment of bowel was filled with a mixture of dog food and 50 plastic pellets before each of 2–5 random sessions of non-stimulated or stimulated emptying. Propagated contractions were generated using microprocessor controlled bipolar trains of 50 Hz rectangular voltage having 20 V (peak to peak) amplitude, 18 second stimulus duration, and a nine second phase lag between stimulation trains in sequential electrode sets.

Results: Electrical stimulation using the above mentioned parameters resulted in powerful phasic contractions that closed the lumen. By phase locking the stimulation voltage between adjacent sets of electrodes, propagated contractions could be produced in an aboral or orad direction. The number of evacuated pellets during the stimulation sessions was significantly higher than during the non-stimulated sessions (p<0.01).

Conclusions: Microprocessor controlled electrical stimulation accelerated movement of colonic content suggesting the possibility of future implantable colonic stimulators.

  • gastric emptying
  • electrical control activity
  • electrical pacing
  • electrical response activity
  • ECA, electrical control activity
  • EP, electrical pacing
  • ERA, electrical response activity
  • HF, high electrical frequency

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Footnotes

  • Note: The technology described in this paper is protected by a pending patent.

Linked Articles

  • Ian Forgacs